ZASTOSOWANIE
Specjalne wykonania wentylatorów TCBT EX do użytku w strefach zagrożenia wybuchem oprócz modeli TCBT/2-250/H 400V-50Hz, TCBT/4-250/H 400V-50Hz, TCBT/6-355/H 400V-50Hz, TCBT/6-400/H 400V-50Hz, dostępne dla TCBT/6-400/H 230/400V-50Hz i większych rozmiarów. Oznaczenie: ATEX 2G Exe II T3, IP55, klasa izolacji F.
Charakterystyki pracy i wymiary zgodnie z danymi wentylatorów TCBT w wykonaniu standardowym.
WYKONANIA SPECJALNE
Modele TCBT/4-710 i 800 mm:
TEMPERATURA PRACY WERSJI ATEX
| Typ | wydajność max | ciśnienie max | moc max |
prędkość obrotowa | natężenie max | napięcie | poziom ciś. akust.* |
temp. min |
temp. max |
masa |
|---|---|---|---|---|---|---|---|---|---|---|
| m3/h | Pa | W | obr./min | A | V | db(A) | oC | oC | kg | |
| TCBT/4-315/H EXEIIT3 | 1950 | 64 | 100 | 1445 | 0.5 | 400 | 51 | -20 | 55 | 11 |
| TCBT/4-355/H EXEIIT3 | 2470 | 74 | 117 | 1415 | 0.5 | 400 | 52 | -20 | 55 | 13.2 |
| TCBT/4-400/H EXEIIT3 | 5140 | 80 | 340 | 1410 | 1.2 | 400 | 60 | -20 | 55 | 15.5 |
| TCBT/4-450/H EXEIIT3 | 6650 | 145 | 525 | 1405 | 1.9 | 400 | 63 | -20 | 55 | 21 |
| TCBT/4-500/H EXEIIT3 | 7590 | 170 | 640 | 1420 | 2.6 | 400 | 66 | -20 | 55 | 25 |
| TCBT/4-560/L EXEIIT3 | 12090 | 205 | 1185 | 1415 | 3.8 | 400 | 68 | -20 | 55 | 33 |
| TCBT/4-560/H EXEIIT3 | 13370 | 190 | 1350 | 1390 | 4.2 | 400 | 69 | -20 | 55 | 34.7 |
| TCBT/4-630/L EXEIIT3 | 16060 | 240 | 1770 | 1410 | 5.9 | 400 | 70 | -20 | 55 | 39 |
| TCBT/4-630/H EXEIIT3 | 17030 | 250 | 1940 | 1400 | 6.2 | 400 | 70 | -20 | 55 | 40 |
| TCBT/4-710/L EXEIIT3 | 20290 | 300 | 2175 | 1435 | 6.4 | 400 | 73 | -20 | 40 | 46 |
| TCBT/4-710/H EXEIIT3 | 26420 | 345 | 3440 | 1460 | 10.6 | 400 | 73 | -20 | 40 | 54 |
| TCBT/4-800/L EXEIIT3 | 29950 | 350 | 3750 | 1460 | 11.3 | 400 | 76 | -20 | 40 | 65 |
| TCBT/4-800/K EXEIIT3 | 34950 | 360 | 5175 | 1460 | 8.8 | 400 | 76 | -20 | 40 | 68 |
| TCBT/4-800/G EXEIIT3 | 38500 | 370 | 6145 | 1470 | 11.1 | 400 | 77 | -20 | 40 | 81 |
| TCBT/4-800/H EXEIIT3 | 42490 | 380 | 7690 | 1475 | 13 | 400 | 78 | -20 | 40 | 89 |
| TCBT/6-355/H EXEIIT3 | 2250 | 28 | 97 | 900 | 0.7 | 400 | 47 | -20 | 55 | 13.2 |
| TCBT/6-400/H EXEIIT3 | 2970 | 29 | 116 | 860 | 0.7 | 400 | 49 | -20 | 55 | 15.5 |
| TCBT/6-450/H EXEIIT3 | 4020 | 66 | 160 | 940 | 0.7 | 400 | 54 | -20 | 55 | 20.7 |
| TCBT/6-500/H EXEIIT3 | 6110 | 78 | 290 | 915 | 1.2 | 400 | 57 | -20 | 55 | 24.8 |
| TCBT/6-560/H EXEIIT3 | 9020 | 105 | 525 | 925 | 2.9 | 400 | 60 | -20 | 55 | 33.5 |
| TCBT/6-630/L EXEIIT3 | 10940 | 105 | 595 | 915 | 2.3 | 400 | 60 | -20 | 55 | 38 |
| TCBT/6-630/H EXEIIT3 | 12620 | 110 | 900 | 960 | 4.8 | 400 | 62 | -20 | 55 | 38.5 |
| TCBT/6-710/H EXEIIT3 | 18550 | 135 | 1320 | 910 | 5 | 400 | 63 | -20 | 55 | 46 |
| TCBT/6-800/H EXEIIT3 | 27910 | 165 | 2345 | 970 | 8.7 | 400 | 68 | -20 | 40 | 80 |
* mierzony w odległości 1.5m od wentylatora.
| Typ | ØA | ØB | C | ØD | ØE | N |
|---|---|---|---|---|---|---|
| mm | mm | mm | mm | mm | mm | |
| TCBT/4-315/H EXEIIT3 | 386 | 355 | 170 | 315 | 10 | 8 |
| TCBT/4-355/H EXEIIT3 | 426 | 395 | 170 | 355 | 10 | 8 |
| TCBT/4-400/H EXEIIT3 | 487 | 450 | 210 | 400 | 12 | 8 |
| TCBT/6-355/H EXEIIT3 | 426 | 395 | 170 | 355 | 10 | 8 |
| TCBT/6-400/H EXEIIT3 | 487 | 450 | 170 | 400 | 12 | 8 |
| Typ | ØA | ØB | C | ØD | ØE | N |
|---|---|---|---|---|---|---|
| mm | mm | mm | mm | mm | mm | |
| TCBT/4-450/H EXEIIT3 | 537 | 500 | 180 | 450 | 12 | 8 |
| TCBT/4-500/H EXEIIT3 | 595 | 560 | 180 | 500 | 12 | 12 |
| TCBT/4-560/L EXEIIT3 | 655 | 620 | 240 | 560 | 12 | 12 |
| TCBT/4-560/H EXEIIT3 | 655 | 620 | 240 | 560 | 12 | 12 |
| TCBT/4-630/L EXEIIT3 | 725 | 690 | 240 | 630 | 12 | 12 |
| TCBT/4-630/H EXEIIT3 | 725 | 690 | 240 | 630 | 12 | 12 |
| TCBT/6-450/H EXEIIT3 | 537 | 500 | 180 | 450 | 12 | 8 |
| TCBT/6-500/H EXEIIT3 | 595 | 560 | 180 | 500 | 12 | 12 |
| TCBT/6-560/H EXEIIT3 | 655 | 620 | 240 | 560 | 12 | 12 |
| TCBT/6-630/L EXEIIT3 | 725 | 690 | 240 | 630 | 12 | 12 |
| TCBT/6-630/H EXEIIT3 | 725 | 690 | 240 | 630 | 12 | 12 |
| TCBT/6-710/H EXEIIT3 | 806 | 770 | 240 | 710 | 12 | 16 |
| Typ | ØA | B | C | ØD | E |
|---|---|---|---|---|---|
| mm | mm | mm | mm | mm | |
| TCBT/4-710/L EXEIIT3 | 806 | 770 | 380 | 710 | 415 |
| TCBT/4-710/H EXEIIT3 | 806 | 770 | 380 | 710 | 444 |
| TCBT/4-800/L EXEIIT3 | 896 | 860 | 380 | 800 | 437 |
| TCBT/4-800/K EXEIIT3 | 896 | 860 | 380 | 800 | 439 |
| TCBT/4-800/G EXEIIT3 | 896 | 860 | 380 | 800 | 447 |
| TCBT/4-800/H EXEIIT3 | 896 | 860 | 380 | 800 | 515 |
| TCBT/6-800/H EXEIIT3 | 896 | 860 | 380 | 800 | 477 |